Typical BOM characteristics

  • Common analog front end across SKUs
  • Sensor head varies per SKU (resistive, capacitive, MEMS)
  • Microcontroller with NVS for calibration data
  • M12 or terminal block interface

Test plan example

  • Power-on self test
  • Sensor reading at three reference points
  • Calibration coefficient calculation and write to NVS
  • Read-back verification of stored calibration
  • Output signal verification (4 to 20 mA, Modbus, or other)

Box-build scope

  • PCBA potted into sealed housing
  • Cable gland or M12 connector
  • Pressure-equalization vent if applicable
  • Label with serial and calibration date

Lead-time pattern

6 to 8 weeks NPI, 3 to 4 weeks repeat batch

Scope split

What we own

  • SMT assembly
  • Calibration test station support
  • Box-build with potting and sealing
  • Per-unit cal data log

What you provide

  • Calibration reference and procedure
  • Sensor head supply
  • Housing parts